ACLS Certification - Official Site | Powered by CPR.com
ACLS Certification - Official Site | Powered by CPR.com Contact Us | 1-800-448-0734 |e-Verify | Log in |

Positive Pressure Ventilation Flashcard 2

Click the hand icon in the lower right corner to see the answer.
Question

To provide free-flowing oxygen via a self-inflating valve to a non vigorous patient in respiratory distress, where should the oxygen hose be connected?

 

a. Through the open reservoir or “tail”
b. At the pop-off valve
c. Into the one-way valve
d. Into the mask cushion

Answer

a. Through the open reservoir or “tail”

Question

When analyzing the normal-pressure time curve of assisted ventilation, which one of the following corresponds to the highest pressure administered to the neonate after each breath?

 

a. Positive-end expiratory pressure
b. Plateau pressure
c. Inspiratory time
d. Peak inspiratory pressure

Answer

d. Peak inspiratory pressure

Question

When preparing a newborn for positive pressure ventilation using a free-flow inflation bag and mask, what is the first thing you should do?

 

a. Adjust the head and neck to open the airway.
b. Use a bulb syringe to remove secretions in the nose and mouth.
c. Apply the mask firmly over the nose and mouth using the E-C clamp technique.
d. Intubate the patient.

Answer

b. Use a bulb syringe to remove secretions in the nose and mouth.

Question

Which device used in giving positive pressure ventilation has a dial that can be adjusted to regulate the gas that can escape after each delivered breath, which in turn enables the adjustment of the positive end-expiratory pressure and continuous positive airway pressure?

 

a. A self-inflating bag
b. A flow-inflating bag
c. A T-piece resuscitator
d. An endotracheal tube

Answer

c. A T-piece resuscitator

Question

Which medical device can measure the pressure delivered during each breath when positive pressure ventilation is being administered during neonatal resuscitation?

 

a. Manometer
b. Central line
c. Capnography
d. Pulse oximeter

Answer

a. Manometer

Question

Which of the following clinical diagnostic procedures is/are pertinent to the diagnosis of a pneumothorax?

 

a. Chest X-ray
b. Auscultation of the chest
c. Transillumination of the chest
d. All of the above

Answer

d. All of the above

Question

Which of the following devices can deliver continuous positive airway pressure (CPAP)?

 

a. A self-inflating bag
b. A nebulizer
c. An endotracheal tube
d. A T-piece resuscitator

Answer

d. A T-piece resuscitator

Question

Which of the following medical devices used for providing positive pressure ventilation spontaneously expands and fills with gas without any source of compressed air?

 

a. T-piece resuscitator
b. Self-inflating bag
c. Flow-inflating bag
d. Anesthesia bag

Answer

b. Self-inflating bag

Question

Which one of the following is the preferred method for delivering positive pressure ventilation to a newly born during neonatal resuscitation?

 

a. E-C clamp technique
b. One-handed technique
c. Two-handed technique
d. It does not matter which method to use because all are appropriate

Answer

c. Two-handed technique

Question

Which one of the following medical conditions is known as air leakage from the lungs that causes an increase in intrathoracic pressure?

 

a. Pneumothorax
b. Pneumonia
c. Tamponade
d. Acute Respiratory Distress Syndrome

Answer

a. Pneumothorax

More Flashcards